With the recent widespread use of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), there have been occasional reports on complications associated with its use. Previous reviews on EBUS-TBNA have been limited to studies by skilled operators, thus the results may not always be applicable to recent clinical practice.

To assess the safety of EBUS-TBNA for the staging and diagnosis of lung cancer in Japan, a nationwide survey on its current usage status and complications associated with its use was conducted by the Japan Society for Respiratory Endoscopy (JSRE).

Methods: A questionnaire about EBUS-TBNA performed between January 2011 and June 2012 was mailed to 520 JSRE-accredited facilities.

Results: Responses were obtained from 455 facilities (87.5%). During the study period, EBUS-TBNA was performed in 7,345 cases in 210 facilities (46.2%) using a convex probe ultrasound bronchoscope, for 6,836 mediastinal and hilar lesions and 275 lung parenchymal lesions.

Ninety complications occurred in 32 facilities. The complication rate was 1.23% (95% confidence interval, 0.97%-1.48%), with hemorrhage being the most frequent complication (50 cases, 0.68%).

Infectious complications developed in 14 cases (0.19%) (Mediastinitis, 7; pneumonia, 4; pericarditis, 1; cyst infection, 1; and sepsis, 1). Pneumothorax developed in 2 cases (0.03%), one of which required tube drainage.

Regarding the outcome of the cases with complications, prolonged hospitalization was observed in 14 cases, life-threatening conditions in 4, and death in 1 (severe cerebral infarction) (mortality rate, 0.01%). Breakage of the ultrasound bronchoscope occurred in 98 cases (1.33%) in 67 facilities (31.9%), and that of the puncture needle in 15 cases (0.20%) in 8 facilities (3.8%).

Conclusions: Although the complication rate associated with EBUS-TBNA was found to be low, severe complications, including infectious complications, were observed, and the incidence of device breakage was high.

Since the use of EBUS-TBNA is rapidly expanding in Japan, an educational program for its safe performance should be immediately established.

Author: Fumihiro AsanoMotoi AoeYoshinobu OhsakiYoshinori OkadaShinji SasadaShigeki SatoEiichi SuzukiHiroshi SembaKazuya FukuokaShozo FujinoKazumitsu Ohmori
Credits/Source: Respiratory Research 2013, 14:50

Published on: 2013-05-10

Copyright by the authors listed above - made available via BioMedCentral (Open Access). Please make sure to read our disclaimer prior to contacting 7thSpace Interactive. To contact our editors, visit our online helpdesk. If you wish submit your own press release, click here.
Social Bookmarking
RETWEET This! | Digg this! | Post to del.icio.us | Post to Furl | Add to Netscape | Add to Yahoo! | Rojo

Comments


Source: http://feedproxy.google.com/~r/7thspaceNews/~3/XKtiBbNMpRo/complications_associated_with_endobronchial_ultrasound_guided_transbronchial_needle_aspiration_a_nationwide_survey_by_the_japan_society_for_respiratory_endoscopy.html

leon russell meredith vieira prop 8 maria menounos proposition 8 ricky martin larry bird

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.